Analysis of the Fracture Failure of ST90 Coiled Tubing

Authors

  • Runqiu Gao
  • Jianliang Duan
  • Jian Dong

DOI:

https://doi.org/10.62051/ijcsit.v5n1.24

Keywords:

Coiled tubing, Hardness test, Metallographic analysis, Fracture

Abstract

This article determines the causes of fracture failure of the ST90 coiled tubing through chemical composition analysis, dimensional measurement, metallographic analysis, and hardness testing of the fractured tubing sample. The material test results show that the chemical composition, size, grain size and hardness test results of the fractured coiled tubing meet the standard requirements, and no abnormal results are found. There is mechanical trauma in the fracture and suspected improper operation on both sides of the fracture position, which causes the tube body damage by the stacking of the clamping blocks, that will cause the deformation of the coiled tubing. The thinning of the wall thickness and the increase of hardness will reduce the strength of the tubing, which is the main reason for the fracture of the coiled tubing.

Downloads

Download data is not yet available.

References

[1] Zhao Jinlan, Cheng Pei, Wang Bin, et al. Fracture Failure Analysis of TS - 90 Coiled Tubing [J]. Welded Pipe and Tube, 2022, 45(06): 39 - 44. DOI: 10.19291/j.cnki.1001 - 3938.2022.06.007.

[2] Wang Weidong, Wang Liang, Wang Chao, et al. Failure Analysis of Coiled Tubing [J]. Chemical Equipment Technology, 2023, 44(02): 45 - 48. DOI: 10.16759/j.cnki.issn.1007 - 7251.2023.04.012.

[3] Tang Guoping. Research on Low - Cycle Fatigue Characteristics and Life Prediction of CT90 Coiled Tubing [D]. China University of Petroleum (Beijing), 2017.

Downloads

Published

11-02-2025

Issue

Section

Articles

How to Cite

Gao, R., Duan, J., & Dong, J. (2025). Analysis of the Fracture Failure of ST90 Coiled Tubing. International Journal of Computer Science and Information Technology, 5(1), 249-255. https://doi.org/10.62051/ijcsit.v5n1.24