Typical Partial Discharge Signal Acquisition and Feature Extraction in High Voltage Switchgear

Authors

  • Jixiang Zeng

DOI:

https://doi.org/10.62051/ijcsit.v3n3.32

Keywords:

Partial discharge, Signal acquisition, Envelope detection

Abstract

With the progress of power system technology, how to effectively evaluate the reliability of high-voltage switchgear equipment has become an important part of power grid power supply and industrial distribution. Switchgear is used in power system power generation, transmission, power distribution, power conversion and consumption play a role in switching, control or protection, voltage level in 3.6kV-550kV electrical products, usually contains a variety of switches, circuit breakers, contactors and other components. In the process of use, due to various reasons, partial discharge may occur. Partial discharge refers to a partial discharge phenomenon in insulating media, which is usually caused by defects in the medium or excessive local electric field intensity. In switchgear, PD may be caused by aging of equipment, deterioration of insulation materials, dust accumulation and other reasons. Pd generates discharge current and discharge heat, which may damage the insulation performance of the equipment or even cause a fire. Therefore, it is very important to detect and deal with the partial discharge phenomenon in the switchgear in time. Therefore, timely detection of partial discharge of equipment can deal with partial discharge problems by checking equipment, cleaning equipment, timely replacement of aging components, and other methods to avoid losses caused by equipment failure due to partial discharge. Due to the complex distribution site environment and the interference of wireless communication signals from other equipment, the real high-frequency signals of partial discharge will be interfered, which will affect the accuracy of insulation performance evaluation of electrical equipment in the switchgear. Therefore, how to correctly collect partial discharge signals and how to identify the characteristics of partial discharge signals will be an important part of partial discharge detection in switchgear. At present, the commonly used partial discharge signal feature recognition is mainly based on the typical signal simulated by Matlab and artificially added noise for processing. Due to the wide frequency band of local discharge and the complex field environment, the real collected waveform will be different from the typical discharge signal. The original signal is filtered and detected for processing and analysis.

Downloads

Download data is not yet available.

References

[1] Li Jie. Research on Insulation Testing Technology of Electric Power Equipment [J]. Gansu Metallurgy, 2010, 32(02):85-87.

[2] Liu Shengjun, Zhao Yuntao, Guo Huiyong, et al. Cause analysis and treatment of 110 kV transformer damage [J]. Insulation Materials, 2014, (1):97-100. DOI:10.3969/j.issn.1009-9239.2014.01.026.

[3] Su Guo-sheng, Yang Shao-fu. Realization of Insulation Aging and Condition Maintenance of High Voltage Equipment [J]. Equipment Manufacturing Technology, 2007(03):15-17.

[4] IEC 60270-1968, Partial Discharge measurement [S].

[5] Yao Chen-guo, ZHOU Wai-bo, Chen Pan, et al. High Voltage Technology, 2011, 037(007):1670- 1676. Chen Peng, Chen Peng, et al. Monitoring and Early Warning of Local Discharge Level of Substation Equipment by Ultra-High Frequency Method [J].

[6] Cheng Yonghong. Insulation Detection and Diagnosis of Power Equipment [M]. China Electric Power Press, 2001.

[7] Li X, Wang X, Xie D, et al. Time-frequency analysis of PD-induced UHF signal in GIS and feature extraction using invariant moments [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12(2):169-175. DOI: https://doi.org/10.1049/iet-smt.2017.0287

[8] Liu S. Research on partial discharge detection technology of GIS based on ultrasonic and ultrahigh frequency method [D].

[9] Zhaoyan, Liuxiaojun. Extracting Partial Discharge Signals of Generator Based on Elevated Minimum Description Length Criterion and Fast Fourier Transform[C]// International Conference on Measuring Technology & Mechatronics Automation. IEEE, 2009. DOI: https://doi.org/10.1109/ICMTMA.2009.407

[10] Brook D. Interest and utility of time frequency and time scale transforms in the partial discharges analysis[M]// The Presbyterian churches and the federal Union, 1861-1869 /. Harvard University Press, 1932.

[11] Xu J, Huang C J. Research on improved Fast Fourier transform frequency domain threshold algorithm in narrowband interference suppression of partial discharge [J]. Electric Power System Technology, 2004(13):80-83.

[12] Satish L, Nazneen B. Wavelet-based Denoising of Partial Discharge Signals Buried in Excessive Noise and Interference [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2003, 10(2):354-367. DOI: https://doi.org/10.1109/TDEI.2003.1194122

[13] Lv Zecheng, Yang Jian, Wu Rongrong, et al. Research and implementation of Wavelet Allfrequency noise reduction Method Based on Adaptive Threshold [J]. Guangxi Electric Power,2019,42(06):13-16+21. Lv Zecheng, Yang Jian, Wu Rongrong, et al. Study and Realization of a Wavelet Full-Frequency Noise Reduction Method Based on Adaptive Threshold [J]. Guangxi Electric Power, 2019, 42(06):13-16+21.

[14] Ge Shaowei, Hou Jianfeng, Kuang Tao, et al. Wavelet adaptive Threshold denoising method for High Voltage Cable Partial Discharge [J]. Electronic Technology and Software Engineering, 2019(20):228-229. Ge Shaowei, Hou Jianfeng, Kuang Tao, et al. Wavelet adaptive threshold denoising method for high voltage cables [J]. Electronic technology and software engineering, 2019(20):228-229.

[15] Lin Meiyan, Tai Chengchi, Tang Yawen, et al. Partial discharge signal extracting using the empirical mode decomposition with wavelet transform[C]// 2011 7th Asia-Pacific International Conference on Lightning, 2011, Chengdu, China: 420-424. DOI: https://doi.org/10.1109/APL.2011.6110158

[16] Tang Y W, Su C C, Tai C C, et al. Cast-resin drytype transformer partial discharge signal analysis using spectral correlated empirical mode decomposition method [J]. 2013. DOI: https://doi.org/10.1109/I2MTC.2013.6555472

[17] Jin T, Li Q, Mohamed M A. A Novel Adaptive EEMD Method for Switchgear Partial Discharge Signal Denoising [J]. IEEE Access, 2019, 7 (1): 58139-58147. DOI: https://doi.org/10.1109/ACCESS.2019.2914064

[18] Yao Linpeng, Zheng Wen-dong, Qian Yong, Du Yong-ping, Yang Fumin, Bi Jie-chang, Huang Cheng-jun, Jiang Xiu-chen. Narrowband Interference Suppression of Partial Discharge Signal Based on Ensemble Empirical Mode Decomposition [J]. Power System Protection and Control, 2011, 39(22):133-139.

[19] Peng Wei-wen, TIAN Mu-qin, SONG Jian-cheng, WEN Min-min, ZHU Jing-jing. A White Noise Suppression Method for Partial Discharge Based on EEMD and Higher Order Statistics [J]. High Voltage Apparatus, 2016, 52(05):54-59+64.

[20] Zhang An 'an, He Jia-hui, Li Qian, Yang Wei, Zhao Wan-ming. Cable Partial amplifier Identification Based on Mathematical Morphology and Fractal Theory [J]. Journal of University of Electronic Science and Technology of China, 2020, 49(01):102-109.

Downloads

Published

12-08-2024

Issue

Section

Articles

How to Cite

Zeng, J. (2024). Typical Partial Discharge Signal Acquisition and Feature Extraction in High Voltage Switchgear. International Journal of Computer Science and Information Technology, 3(3), 307-323. https://doi.org/10.62051/ijcsit.v3n3.32