Motor protection as one of the protection measures of power electronic system, has always been conservative attention, the content of this paper is based on the communication process of low-voltage motor protection. This paper discusses from the perspective of cost reduction and efficiency enhancement and industrial capability enhancement. Therefore, VPC3 chip of Siemens is not used as the protocol package of Profibus communication, and its packet and decoding are both using MCU internal resources. Modbus, as a simple and easy to understand communication mode, is used as the underlying data exchange library of Profibus. Profibus communication protocol only needs to encapsulate Modbus for motor protection, and realizes two communication protocols for motor protection controller. In this connection, a communication scheme based on STM32 Modbus-PROFIBUS motor protection controller is proposed.

Downloads

Download data is not yet available.

References

[1] Yang Haodong. Design and Implementation of Electrical Information Acquisition Subsystem based on Modbus [D]. University of Electronic Science and Technology of China, 2019:6-9.

[2] HAO Z J, ASADULLAH A, WAWALE S. Application of MODBUS double-layer communication network technology in intelligent management of urban traffic equipment [J]. International Journal of System Assurance Engineering and Management, 2021, 13(Suppl 1): 25-28.

[3] WAN Y, FENG X N, CHEN Y X. A Dual Detection Method for Siemens Inverter Motor Modbus RTU Attack [J]. Journal of Computer and Communications, 2021, 09(07): 44-48.

[4] PALLAVI D. Design and Implementation of Circuit Analysis System for Industrial Watt-hour Meter based on MODBUS Protocol [J]. International Journal of Power and Energy Engineering, 2020, 2(1): 15-28.

[5] WENQIAN F, YINGXU L, ZENGHUI L. Vulnerability mining for Modbus TCP based on exception field positioning [J]. Simulation Modelling Practice and Theory, 2020: 15- 18.

[6] CHRISTOPHER P, TERRY G, SAJAL B. Fooling the Master: Exploiting Weaknesses in the Modbus Protocol [J]. Procedia Computer Science, 2020, 171(C): 35-46.

[7] Zong Zhenyan. Design of Fault Automatic Diagnosis System for Electric control Board of Variable frequency Air Conditioner [D]. Shandong University of Science and Technology, 2020:13-28.

[8] WANG Chao. Research on Modbus Communication Protocol and its Application in Oilfield Control System [J]. Instrument User, 2014, 21(02): 51-53.

[9] Lv Guohua, Cheng Guanghe, Fangli Zhen. Implementation of Modbus Communication Based on ARM7 microprocessor [J]. Information Technology and Informatization, 2010(05): 45-47.

[10] Zhu Jing, Qi Xiangdong. Communication between IFIX and PLC Based on OPC, Modbus and ModbusTCP/IP [J]. Electronic Devices, 2013, 36(2): 260-264.

[11] Dou Yan-nan, Meng Qing-Yao, Ding Qi. Analysis of Modbus Protocol and Security Based on Wireshark [J]. Network Security Technology and Application, 2021(06):4-6.]

[12] Wang Zhebei, Li Zhuo, Lu Haisong, et al. Overview of Typical Fieldbus protocols for Communication networks [J]. Industrial Control Computer, 2021, 34(11):5-8+11.

[13] Wang P, Zhang Y F, Guo H. et al. Design of Profibus-DP Wireless Communication Module [J]. 2nd International Conference on Signal Image Processing and Communication, 2022, 12246:156-160.

Downloads

Published

12-08-2024

Issue

Section

Articles

How to Cite

Run, Z. (2024). Communication Scheme of Modbus-Profibus Motor Protection Controller Based on STM32. International Journal of Computer Science and Information Technology, 3(3), 258-271. https://doi.org/10.62051/ijcsit.v3n3.27