Analysis and Research on Anti-Condensation Performance of Molten Salt Control Valve

Authors

  • Jiabin Zhang
  • Zegang Sun
  • Zhonghao Zhang

DOI:

https://doi.org/10.62051/ijmee.v7n3.01

Keywords:

Molten Salt Solidification, Molten Salt Control Valve, Solidification Temperature, Optimized Design

Abstract

During the molten salt flow process in the molten salt control valve, localized temperatures may fall below the solidification point of the molten salt, leading to partial solidification within the valve body and consequently affecting the flow performance of the valve. This study conducts temperature and flow field simulations under various operating conditions to investigate the potential occurrence of solidification during the molten salt flow process. Specifically, it analyzes whether the molten salt temperature drops below its solidification point under three extreme scenarios: fully open valve position, sudden valve closure with residual molten salt remaining in the valve body, and abrupt flow interruption due to pipeline equipment failure. The research findings demonstrate that molten salt solidification does not occur in any of these three scenarios, providing valuable reference data for subsequent optimization design of molten salt control valves.

References

[1] MU Shihui, Yu Siyuan, Zhao Shuguang. Application Status and Optimization of Heat Tracing of Molten Salt Valve in Molten Salt Energy Storage System [J]. Energy and Energy Conservation, 2022, 207(12): 28-32.

[2] SHEN Xiaolei, Chen Haitao. A Brief Analysis of the Application of Electric Trace Heating in Molten Salt Systems of Solar Thermal Power Generation [J]. Electric Power Equipment Management, 2024, 19(8): 131-133.

[3] HU Yonghai, Lu Jiaming. Analysis of the Temperature Field of Molten Salt Shut-off Valve of the Solar Thermal Power Station[J]. Northwest Hydropower, 2022, 41(2): 106-110.

[4] WU Wangsong, KUANG Jingzhu, MAO Zhengjiang, et al. Study on melting process of molten salt in pipe equipped with a built-in electric tracing heater[J]. Thermal Power Generation, 2022, 51(3): 79-87.

[5] Shi Yufeng. Design of Electric Tracing and Anticoagulation System for Molten Salt Linear Fresnel Heat Field[D]. Lanzhou: Lanzhou Jiaotong University, 2022.

[6] SHEN Hengyun.Numerical Simulation of CFD Three-Dimensional Opening and Closing Dynamic Characteristics of Molten Salt Swing Check Valve for Solar Power Generation [D]. Lanzhou: Lanzhou University of Technology, 2022.

[7] LIU Wenxiang. Research on Valve Disc Construction and Anti-erosion of Control Valve Used for High Temperature Molten Salt[D].Suzhou:Soochow University, 2019.

[8] LI SHUXUN, SHEN HENGYUN, et al. Pressure Pulse Response of High Temperature Molten Salt Check Valve Hit by Crystal Particles[J]. Journal of Shanghai Jiao Tong University,2023,29(3):271-279.

Downloads

Published

26-12-2025

Issue

Section

Articles

How to Cite

Zhang, J., Sun, Z., & Zhang, Z. (2025). Analysis and Research on Anti-Condensation Performance of Molten Salt Control Valve. International Journal of Mechanical and Electrical Engineering, 7(3), 1-8. https://doi.org/10.62051/ijmee.v7n3.01